Interior support

Support in electrical system construction

Special components to support and secure electrical components.

Interior support LUKA GmbH

Indoor supports

Indoor supports are ideal components used in electrical installations within buildings to support and secure electrical components such as switchboards and circuit boards. They are designed to ensure the structural integrity of installations while increasing electrical safety. Thanks to their robust construction, indoor supports offer a reliable solution that meets the high demands of modern electrical installations.

Filter interior supports

A12N-1-M10+M16

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 130
  • Diameter in mm: 60
  • Bending strength in kN: 5
  • Creepage distance in mm: 174
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 75
  • Foot fitting: M16x33
  • Head fitting: M10x16
  • Permissible operating voltage in kV: 12 kV
To the statements

A12S-1-M10+M16

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 95
  • Diameter in mm: 60
  • Bending strength in kN: 5
  • Creepage distance in mm: 133
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 60
  • Foot fitting: M16x33
  • Head fitting: M10x16
  • Permissible operating voltage in kV: 12 kV
To the statements

A12S-1-M10+M12

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 95
  • Diameter in mm: 60
  • Bending strength in kN: 5
  • Creepage distance in mm: 133
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 60
  • Foot fitting: M12x30
  • Head fitting: M10x16
  • Permissible operating voltage in kV: 12 kV
To the statements

A12S-2-M10+M16

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 95
  • Diameter in mm: 60
  • Bending strength in kN: 5
  • Creepage distance in mm: 133
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 60
  • Foot fitting: M16x33
  • Head fitting: M10x16
  • Permissible operating voltage in kV: 12 kV
To the statements

A12S-1-M12+M16

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 95
  • Diameter in mm: 60
  • Bending strength in kN: 5
  • Creepage distance in mm: 133
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 60
  • Foot fitting: M16x33
  • Head fitting: M12x18
  • Permissible operating voltage in kV: 12 kV
To the statements

A12N-2-M10+M16

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 130
  • Diameter in mm: 60
  • Bending strength in kN: 5
  • Creepage distance in mm: 174
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 70
  • Foot fitting: M16x33
  • Head fitting: M10x20
  • Permissible operating voltage in kV: 12 kV
To the statements

B12S-1-M16

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 95
  • Diameter in mm: 72
  • Bending strength in kN: 10
  • Creepage distance in mm: 133
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 60
  • Foot fitting: M16x25
  • Head fitting: M16x25
  • Permissible operating voltage in kV: 12 kV
To the statements

B12N-1-M16+M20

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 130
  • Diameter in mm: 72
  • Bending strength in kN: 10
  • Creepage distance in mm: 187
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 75
  • Foot fitting: M20x34
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 12 kV
To the statements

C12N-1-M16+M20

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 130
  • Diameter in mm: 90
  • Bending strength in kN: 16
  • Creepage distance in mm: 195
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 75
  • Foot fitting: M20x34
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 12 kV
To the statements

D12N-3-M16+M24

Cast resin interior support 12kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 130
  • Diameter in mm: 130
  • Bending strength in kN: 25
  • Creepage distance in mm: 261
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 75
  • Foot fitting: M24x35
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 12 kV
To the statements

A24S-1-M10+M16

Cast resin interior support 24kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 175
  • Diameter in mm: 70
  • Bending strength in kN: 5
  • Creepage distance in mm: 258
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 95
  • Foot fitting: M16x33
  • Head fitting: M10x16
  • Permissible operating voltage in kV: 24 kV
To the statements

A24S-1-M12+M16

Cast resin interior support 24kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 175
  • Diameter in mm: 70
  • Bending strength in kN: 5
  • Creepage distance in mm: 258
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 95
  • Foot fitting: M16x33
  • Head fitting: M12x18
  • Permissible operating voltage in kV: 24 kV
To the statements

A24N-1-M10+M16

Cast resin interior support 24kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 210
  • Diameter in mm: 70
  • Bending strength in kN: 5
  • Creepage distance in mm: 296
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 125
  • Foot fitting: M16x33
  • Head fitting: M10x16
  • Permissible operating voltage in kV: 24 kV
To the statements

A24N-1-M12+M16

Cast resin interior support 24kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 210
  • Diameter in mm: 70
  • Bending strength in kN: 5
  • Creepage distance in mm: 296
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 125
  • Foot fitting: M16x33
  • Head fitting: M12x18
  • Permissible operating voltage in kV: 24 kV
To the statements

B24S-1-M16+M20

Cast resin interior support 24kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 175
  • Diameter in mm: 80
  • Bending strength in kN: 10
  • Creepage distance in mm: 259
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 95
  • Foot fitting: M20x34
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 24 kV
To the statements

B24N-1-M16+M20

Cast resin interior support 24kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 210
  • Diameter in mm: 85
  • Bending strength in kN: 10
  • Creepage distance in mm: 308
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 125
  • Foot fitting: M20x34
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 24 kV
To the statements

B24N-2-M16+M20

Cast resin interior support 24kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 210
  • Diameter in mm: 85
  • Bending strength in kN: 10
  • Creepage distance in mm: 308
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 125
  • Foot fitting: M20x34
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 24 kV
To the statements

B24F-1-M16+M20

Cast resin interior support 24kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 210
  • Diameter in mm: 98
  • Bending strength in kN: 10
  • Creepage distance in mm: 417
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 125
  • Foot fitting: M20x34
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 24 kV
To the statements

A36N-1-M10+M16

Cast resin interior support 36kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 300
  • Diameter in mm: 80
  • Bending strength in kN: 5
  • Creepage distance in mm: 434
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 170
  • Foot fitting: M16x33
  • Head fitting: M10x16
  • Permissible operating voltage in kV: 36 kV
To the statements

A36N-2-M10+M16

Cast resin interior support 36kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 300
  • Diameter in mm: 80
  • Bending strength in kN: 5
  • Creepage distance in mm: 434
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 170
  • Foot fitting: M16x33
  • Head fitting: M10x16
  • Permissible operating voltage in kV: 36 kV
To the statements

B36N-1-M16+M24

Cast resin interior support 36kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 300
  • Diameter in mm: 95
  • Bending strength in kN: 7.5
  • Creepage distance in mm: 434
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 170
  • Foot fitting: M24x35
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 36 kV
To the statements

B38.5F-1-M16+M24

Cast resin interior support 38.5kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 325
  • Diameter in mm: 98
  • Bending strength in kN: 10
  • Creepage distance in mm: 546
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Rated AC voltage in kV: 180
  • Foot fitting: M24x35
  • Head fitting: M16x33
  • Permissible operating voltage in kV: 38,5 kV
To the statements

30/30-M8 GH

Cast resin interior support 2kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 30
  • Diameter in mm: 33
  • Bending strength in kN: 3
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Tensile strength in kN: 6
  • Foot fitting: M8x8
  • Head fitting: M8x8
  • Permissible operating voltage in kV: 2 kV
To the statements

60/60-M12GH

Cast resin interior support 3kV

Support insulator made of epoxy cast resin for indoor systems

  • Total length in mm: 0
  • Height in mm: 60
  • Diameter in mm: 60
  • Bending strength in kN: 12.5
  • Temperature range in °C: -40/+90 °C
  • Indoor/outdoor system: Indoor facility
  • Tensile strength in kN: 22.5
  • Foot fitting: M12x18
  • Head fitting: M12x18
  • Permissible operating voltage in kV: 3 kV
To the statements